Temperature and Humidity Test Chamber

Environmental Test Chamber

LAB1ST temperature and humidity test chamber is a specialized enclosure designed to simulate and control environmental conditions of temperature and humidity for the purpose of testing various materials, products, and components.

 

These chambers play a critical role in industries such as electronics, automotive, pharmaceuticals, and materials science by providing controlled environments that mimic real-world conditions. 

TC1000F主图2_edited.png
_MG_0577_edited.jpg
0531-1_edited.jpg

Product Range

TCH100V.png

TCH*F Series

Standard chambers for most general applications

  • Temperature: -40℃~150℃ [-40°F~302°F]

  • Humiditiy: 20% to 98% RH

  • Interior Sizes: 50L, 100L, 250L, 500L, 1000L or larger

TCH100F主图4.png

TCH*V Series

Wider temperature control range, down to -70℃

  • Temperature: -70℃~150℃ [-94°F~302°F]

  • Humiditiy: 20% to 98% RH

  • Interior Sizes: 50L, 100L, 250L, 500L, 1000L or larger

主图1.png

TCH*V-R Series

Faster temperature cycling of 5 to 15°C/min

  • Operating Temp. Range: -70℃~150℃ [-94°F~302°F]

  • Rapid Temp. Change Range: -40~120 ℃ [-40°F~ 248°F]

  • Rapid Temp. Cycling Rate: 5°C/min, 10°C/min, and 15°C/min

  • Interior Sizes: 50L, 100L, 225L, 500L, 1000L larger

Customized Projects

Key Facts

Temperature Control

0806-1.jpg

Typically control temperatures from below freezing to very high temperatures, such as -70℃~150℃ [-94°F~302°F] and -40℃~150℃ [-40°F~302°F]. 

Humidity Control

0806-2.jpg

Regulate humidity levels, creating conditions from very dry to highly humid environments, standard 20% - 98% RH, or optional 10%-98% RH / 2%-10% RH.

Rapid Heating/Cooling Change

0806-3.jpg

Our TCH-V-R series chambers achieve rapid heating and cooling rates with 5°C/min, 10°C/min, and 15°C/min. 

Specifications

Series
TCH*F
TCH*V
TCH*V-R*
Model
TCH50F, TCH100F, TCH225F, TCH500F, TCH1000F
TCH50V, TCH100V, TCH225V, TCH500V, TCH1000V
TCH*V-R5, TCH*V-R10, TCH*V-R15
Type
Floor-stand reach-in design
Floor-stand reach-in design
Floor-stand reach-in design
Temperature Range
-40°C to 150°C
-70°C to 150°C
-70°C to 150°C
Rapid Temperature Change Range
-40° to 120°C
Humidity Control
20% - 98% RH
20% - 98% RH
20% - 98% RH
Standard Chamber
50L, 100L, 225L, 500L, 1000L
50L, 100L, 225L, 500L, 1000L
50L, 100L, 225L, 500L, 1000L
Heating Rate
3.0-5.0 C/min
3.0-5.0 C/min
R5: 5 C/min R10: 10 C/min R15: 15 C/min
Cooling Rate
0.7-1.5 C/min
0.7-1.5 C/min
R5: 5 C/min R10: 10 C/min R15: 15 C/min
Model
TCH50F, TCH100F, TCH250F, TCH500F, TCH1000F
TCH50V, TCH100V, TCH250V, TCH500V, TCH1000V
TCH*V-R5, TCH*V-R10, TCH*V-R15

Applications

Electronics

Testing electronic components and devices for reliability and performance under different climate conditions.

Automotive

Assessing the durability of automotive parts and systems to ensure they can withstand varying environmental conditions.

Pharmaceuticals

Testing drug stability and packaging under controlled humidity and temperature conditions.

Materials Science

Studying how different materials degrade or behave in response to environmental changes.